Apex Lift ControlsQuote

Original Tier-2 OEM · Vancouver, BC

CE marking

Conformity

CE marked

KF-9074 /
KF-9075
Elevator safety contact switches, engineered so the spring never carries current.

The fixed safety contact base and its mating moving contact bridge, CE marked under the Low Voltage Directive and assessed to IEC 60947-5-1 and EN81-1, -2. Current is routed through a braided copper shunt; the stainless return springs stay electrically isolated. Shipped factory vacuum-sealed.

Ith
2 A
Ue
230 VAC · 200 VDC
Category
AC-15 ; DC-13
Mark
CE

Engineering failure analysis

Separate the force path from the current path.

As you scroll, the KF-9075 bridge plunges into the KF-9074 base. At full travel the contacts close and 2 A at up to 200 VDC flows — through copper, never through steel.

  1. FM-01

    Spring-borne current

    When a return spring doubles as the conductor, I²R heating at the contact interface flows into the spring itself. Repeated thermal cycling can relax spring force — and contact pressure falls with it.

    Stainless steel coil springs are electrically isolated. They provide force only: zero current, zero Joule heat.

  2. FM-02

    Uncontrolled current path

    Current that finds its own way through pivots and sliding surfaces produces unpredictable resistance and localised hot spots.

    A dedicated 12×43/0.05 braided copper shunt carries the full 2 A rated current from terminal to moving contact.

  3. FM-03

    Silver-alloy oxidation in storage

    Silver-alloy contacts tarnish in humid or sulphur-bearing air while parts sit in a stores cabinet, raising initial contact resistance.

    Every unit leaves the factory vacuum-sealed, so contacts arrive in as-manufactured condition.

Technical data

Electrical ratings & envelope

CE marking

Conformity

CE marked

Low Voltage Directive 2014/35/EU · IEC 60947-5-1 · EN 81-1 · EN 81-2

Standards
IEC 60947-5-1 · EN81-1 · EN81-2
Conventional thermal current
Ith = 2 A
Rated operational voltage
Ue = 230 VAC; 200 VDC
Rated operational current
Ie = 2 A
Utilization categories
AC-15 ; DC-13
AC-15: AC electromagnetic loads · DC-13: DC electromagnets
KF-9074 base envelope
73 × 27.5 mm
KF-9074 mounting pitch
29 mm
KF-9075 bridge envelope
40.5 × 12.1 mm
Current path
Braided copper shunt 12×43/0.05
Return springs
Stainless steel, electrically isolated
Delivery
Factory vacuum-sealed

Cross-reference

One part, every number on your work order

Search by any of these references — they all resolve to the KF-9074 / KF-9075 pair supplied here.

  • KF-9074

    Safety contact base

  • KF-9075

    Actuator bridge

  • 2L1A000001

    OEM reference

  • 2L1A000001V01

    OEM reference, V01 revision

  • 6400.00.0001CN

    OEM reference

  • 6400.00.0001CNV01

    OEM reference, V01 revision

  • WITTUR CN0229

    Interchange reference

Delivery condition

Factory vacuum-sealed.

Silver-alloy contacts begin to oxidise the moment they meet humid, sulphur-bearing air. Each switch is vacuum-sealed at the factory, so the contact surfaces your technician installs are the surfaces that left the line — not ones that aged on a shelf.

VACUUM-SEALED · AIR EVACUATEDKF-9074 + KF-9075 · CE

Quotes & samples

Request KF-9074 / KF-9075 pricing

For elevator OEMs, modernisation contractors and maintenance fleets across North America. Units are CE marked under the Low Voltage Directive. Tell us the cross-reference on your work order and the volume you need.

Apex Lift Controls · Vancouver, BC, Canada

Request type
Parts